qPCR with no amplification or late Cq: causes and fixes

Your controls usually say what went wrong. A positive control, a no-template control, a no-RT control and one dilution of the sample separate template, inhibition and primer problems.

Range: qPCR and RT-PCR reagents3 minute readUpdated

Researcher loading sample tubes into a benchtop instrument
On this page
  1. Key points
  2. Let the controls decide
  3. No amplification at all
  4. Late Cq and poor efficiency
  5. Extra melt peaks and signal in the NTC
  6. Reagents for a repeat run
  7. Questions

Key points

  • If the positive control fails too, the problem is the mix, the primers or the instrument setup. If only your samples fail, it is the template.
  • Signal in the no-template control means contamination or primer dimers; the melt curve tells them apart.
  • A late Cq that improves on dilution points to inhibitors in the sample.
  • Signal in the no-RT control means genomic DNA is being amplified.

Let the controls decide

Reading qPCR controls
ResultMeaningNext step
Positive control failsMix, primers, cycling or instrumentCheck dye channel, ROX setting, cycling program
Positive control works, samples do notTemplate or reverse transcriptionRNA quality, RT step, input amount
Signal in the no-template controlContamination or primer dimersInspect the melt curve
Signal in the no-RT controlGenomic DNA amplifyingDNase treat; span an exon junction
Replicates scatter, Cq above about 35Too few template copiesAdd more input; expect noise at low copy

No amplification at all

  • Wrong channel or reference dye setting. The instrument must read your dye, and the ROX level must match the master mix. The master mix guide lists what each instrument expects.
  • Hot-start not activated. Use the initial activation time on the datasheet. Antibody hot-start mixes often need 2–3 minutes; chemical hot-start can need longer.
  • A failed reverse transcription. Include a reference gene known to express in your sample, and check that the RNA is intact.
  • Primers against the wrong sequence. Check them against the current transcript, for your species, with a sequence search.

Late Cq and poor efficiency

A later Cq than expected means less amplifiable template, or an assay that is not doubling each cycle. Efficiency is calculated from a dilution series: a slope of about -3.3 is 100%, and 90–110% (slopes of about -3.6 to -3.1) is the usual acceptable window.

  • Inhibition. Dilute the sample 1:5 or 1:10. Each 10-fold dilution should delay Cq by about 3.3 cycles. If Cq stays the same or improves, something in the sample was inhibiting the reaction. Common inhibitors include heparin, heme, polysaccharides and carried-over ethanol or salts.
  • Degraded or impure RNA. See low RNA yield and poor A260/230.
  • Poor primers. Redesign rather than endlessly optimising. Short amplicons of about 70–150 bp amplify most efficiently.

Extra melt peaks and signal in the NTC

With a dye such as SYBR Green, a clean assay shows one sharp melt peak. Primer dimers appear as a separate peak at a lower temperature, usually in the no-template control too. A peak at the same temperature as your product in the no-template control means real contamination.

  • For dimers: raise the annealing temperature, lower the primer concentration or redesign.
  • For contamination: replace the water and primer aliquots, separate pre- and post-PCR areas, use filter tips and never open finished plates in the setup area.

Reagents for a repeat run

When only one component is in doubt, replace it rather than the whole workflow. The qPCR and RT-PCR range covers premixes, Taq and reverse transcription kits. See PCR vs qPCR vs RT-qPCR for which reagent each method needs.

Questions we get asked

Why is there no amplification in my qPCR?

Check the positive control first. If it also fails, look at the dye channel, the ROX setting, the cycling program and the master mix. If it works, the problem is the template or the reverse transcription.

What does amplification in the no-template control mean?

Either contamination or primer dimers. In a dye-based assay, a melt peak at the same temperature as the product means contamination; a lower-temperature peak means primer dimers.

What is an acceptable qPCR efficiency?

Usually 90–110%, equal to a standard-curve slope of about -3.6 to -3.1. A slope of about -3.3 corresponds to 100% efficiency.

How can I test for PCR inhibitors?

Run the sample neat and diluted. Each 10-fold dilution should delay Cq by about 3.3 cycles. If the diluted sample comes up as early as or earlier than the neat one, inhibitors are likely.

Sources

  1. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Bustin SA et al. Clin Chem. 2009;55:611-22.
  2. qPCR primer design revisited. Bustin S et al. Biomol Detect Quantif. 2017;14:19-28.
  3. A practical approach to RT-qPCR-Publishing data that conform to the MIQE guidelines. Taylor S et al. Methods. 2010;50:S1-5.
  4. PCR inhibitors - occurrence, properties and removal. Schrader C et al. J Appl Microbiol. 2012;113:1014-26.

For research use only. Protocols here are general outlines: follow your kit manual and your institution’s safety rules. See our editorial policy.

Products for this workflow

qPCR and RT-PCR reagents

Taq DNA polymerase, PCR and qPCR premixes, and reverse transcription kits for cDNA synthesis.

Need the reagents for this?

Send the product names or catalogue numbers, quantities and delivery country. We'll confirm availability, lead time and the documents for qpcr and rt-pcr reagents.